DC100K
Cardinal Scale’s DC series SmartCell® stainless steel compression digital load cells daisy-chain together for ease of wiring and the cables connect automatically to the load cell. Internal load cell circuitry eliminates the need for a junction box. The OIML-certified DC series come in either 22,700 kg / 50,000 lb or 45,000 kg / 100,000 lb capacities and they include iSite remote diagnostic monitoring software with automatic text/e-mail alerts. The DC series feature SmartCal for easy calibration, anti-rotation, and extra robust upper and lower cups. The stainless steel IP69K-rated DC series may be interchangeable with Cardinal Scale’s SCA load cells for complete digital conversions on vehicle scales and tank/hopper scales. Sense leads are no longer required like in analog load cells since variations in systems voltage no longer affect the load cell.
- 22700 kg / 50000 lb and 45000 kg / 100000 lb Capacities
- Anti-Rotation Mounting
- Cables Connect Automatically to Load Cells
- Daisy-Chain Cells Together for Ease of Wiring
- Extra Robust Upper and Lower Cups
- Includes iSite Remote Diagnostics Software with E-mail and Text Alerts
- Interchangeable with Cardinal SCA Load Cells for Complete Digital Conversions
- IoT-Enabled Digital Load Cells
- IP69K Rated for High-Pressure and High-Temperature Washdown Applications
- No Junction Box Necessary
- Stainless Steel Load Cells
Capacity (Model DC-50K): 22,700 kg / 50,000 lb
Capacity (Model DC-100K): 45,000 kg / 100,000 lb
Cell Type: Digital compression load cell
Rated Output: Cardinal digital output
Protection Class: IP69K
Connectors: 5-Pin, M12 Male, A-Coding
Construction: Stainless Steel
OIML Certification: R60/2000-GB1-17.18
Includes: iSite remote diagnostic monitoring software with e-mail and text alerts
Mounting: Extra robust upper and lower receiver cups
Min. Dead Load: 0%Ln
Service Load: 120%Ln
Safe Load Limit: 200% Rated Capacity
Accuracy Class: 4,000 n. OIML
Total Error: < ±0.013%Sn
Repeatability Error: < ±0.015%Sn
Temperature Effect on Zero: < ±0.01%Sn/5 °C
Temperature Effect on Sensitivity: < ±0.006 %Sn/5 °C
Creep Error: < ±0.012 %Sn
Input Voltage Range: 12 V – 24 V
Insulation Resistance: > 5000 MΩ
Maximum Deflection (at Ln): 0.6-1 mm
Temperature Compensation: -10 to +40˚C
Temperature Limits: -50 to +60˚C (OIML certified up to +40˚C)